Bien-Air Medical Technology

Aquilon Instructions May 2011

Instructions

2 Pages

3,1 bar  2 - 3V 4V Unifix  Aquilon Do not sterilise fig. 1  A B C  Instruction 0120  REF 2100033-ENG/05.11  English Medical devices entirely made in Switzerland by Bien-Air Dental SA. Type Dental air micromotor, non-sterilisable. Description Aquilon with internal or external spray, without light as per ISO Standard 3964. Intended use Product intended for professional use only. Use in dentistry for prophylaxis, general dentistry and endodontic work.  Servicing Never disassemble the device. For any modification and repair, we recommend that you contact your regular supplier or Bien-Air Dental directly. BienAir Dental asks the user to have its dynamic instruments checked or inspected at least once a year.  Never immerse in disinfectant solutions.  Classification Class IIa in accordance with European Directive 93/42/EEC concerning medical devices.  Lubrication Lubrication at least twice a day. Only use the spray Lubrifluid. • Place the device in a cloth so as to catch the debris and foreign matter expelled by the atomizer jet. • Insert the nozzle into the back of the instrument sleeve. Spray for about 1 second fig. 5.  Dimensions Ø 23 x 65 mm Weight 90 g without the cable. Recommanded rotation speed 5,000 rpm up to 25,000 rpm; rotation in both directions, positions A, B and C fig. 2. Mechanical power 16 W Torque 25 mNm  Transport and storage conditions Temperature between -40°C (-40°F) and 70°C (158°F), relative humidity between 10% and 100%, atmospheric pressure 50 kPa to 106 kPa (7.3 to 15.3 psi). Information The technical specifications, illustrations and dimensions contained in these instructions are given only as a guide. They may not be the subject of any claim. The manufacturer reserves the right to make technical improvements to its equipment, without amending these instructions. For all additional information, please contact Bien-Air Dental SA at the address indicated on the back cover. Other precautions for use  Noise level In accordance with ISO 11498, less than 70 dBA at 45 cm (17.72 in). Air consumption output 56 normliter/min on average. Required air pressure Adjust the required air pressure to 3.1 bar with the assistance of a Bien-Air Dental inspection pressure gauge - 3-hole version or 4-hole version, placed between hose and Unifix coupling, fig. 1. Changing the seals fig. 3 Maintenance Non-sterilisable Clean and lubricate the device before the treatment of each patient. Only use maintenance products and components from Bien-Air Dental. The use of other products and components can void the guarantee. REF 2100033-ENG/05.11  B  Disinfection Disinfect using a clean cloth soaked in a suitable product. Products containing acetone, chlorine and bleaches are not recommended as disinfectants.  Not suitable for ultrasonic bath.  Important Never mount an instrument on a rotating motor.  1 sec.  A  Cleaning Carefully clean all surfaces with a cloth impregnated with Spraynet, fig. 4.  Technical data and assembly  Coupling For 2-3- or 4-way coupling, fig. 1  fig. 3  fig. 2  The device must be used by a qualified person in accordance with the current legal provisions concerning industrial safety, health and accident prevention measures, and these working instructions. In accordance with these requirements, the operators: • must only use operating devices that are in perfect working order; in the event of irregular functioning, excessive vibration, abnormal heating or other signs indicating malfunction of the device, the work must be stopped immediately; in this case, contact a repair centre that is approved by Bien-Air Dental; • must ensure that the device is used only for the purpose for which it is intended, must protect themselves, their patients and third parties from any danger, and must avoid contamination through the use of the product. The device is intended for medical treatment only; any use other than that for which this product is intended is unauthorised and may be dangerous. The medical device meets all the current legal requirements.  fig. 4  fig. 5  Recommendations It is essential to use dry, purified compressed air in order to ensure the long working life of the device. Maintain the quality of the air and the water by regular maintenance of the compressor and the filtration systems. The use of unfiltered hard water will lead to early blockage of the tubes, connectors and spray cones.  Claims under the terms of the guarantee will be considered only on presentation, together with the product, of the invoice or the consignment note, on which the date of purchase, the product reference and the Serial No. should be clearly indicated.  Rest the device on a suitable support to avoid risks of infection for yourself, the patient or third parties. Guarantee Terms of guarantee Bien-Air Dental grants the user a guarantee covering all functional defects, material or production faults. The device is covered by this guarantee for 12 months from the date of invoicing. Bien-Air Dental offers a 24-month guarantee for the glass-bar light conductors. In the event of justified claim, Bien-Air Dental or its authorised representative will fulfil the company’s obligations under this guarantee by repairing or replacing the product free of charge. Any other claims, of whatever nature, in particular in the form of a claim for damages and interest, are excluded. Bien-Air Dental shall not be held responsible for damage or injury and the consequences thereof, resulting from: • excessive wear and tear • improper use • non-observance of the instructions for installation, operation and maintenance • unusual chemical, electrical or electrolytic influences • poor connections, whether of the air, water or electricity supply. The guarantee does not cover flexible “fibre optic” type conductors, or any parts made of synthetic materials. The guarantee shall become null and void if the damage and its consequences are due to improper manipulation of the product, or modifications to the product carried out by persons not authorised by Bien-Air Dental. 1/2
File Type: PDF
File Size: 229 KB
File Name: aquilon_instructions_may_2011.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions