Angel cPRP System Processing Set Instructions for Use Sept 2013

Processing Set Instructions for Use

7 Pages

CONCENTRATED PLATELET RICH PLASMA (cPRP) SYSTEM Processing Set GB -  ENGLISH  Instructions for Use Catalog No. 976000501 976000601  SET CONTENTS  Figure 1 - Angel® Whole Blood Separation Processing Set Figure 1 - Angel® cPRP Processing Set Variable Volume Separation Chamber: The Angel® Whole Blood Separation Processing Set utilizes a variable volume separation chamber that can process from 40 ml – 180 ml of anticoagulated autologous whole blood in a single cycle. Variable Volume Separation Chamber: The Angel® cPRP Processing Set utilizes a variable volume separation chamber that can process from 40 ml – 180 ml of anticoagulated autologous whole blood or a mixture of blood and bone marrow in a Platelet Cuvette/Valve Assembly: The platelet cuvette/valve assembly contains three major components: (1) the platelet single cycle. cuvette, (2) the pump loop tubing and (3) the rotating valve. Platelet Cuvette/Valve Assembly: The platelet cuvette/valve assembly contains three major components: (1) the platelet The top(2) half the variable volume separation chamber cuvette, theofpump loop tubing and (3) the rotating valve. (Figure 1) is the separation chamber plate. The separation chamber plate is used to seat the variable volume separation chamber in the centrifuge. The top half of the variable volume separation chamber (Figure 1) is the separation chamber plate. The separation chamber The platelet cuvette/valve assembly hasseparation been designed so that operator can easily install the platelet cuvette/valve plate is used to seat the variable volume chamber in thethe centrifuge. assembly while insuring that the platelet cuvette is properly seated in the platelet sensor and that the rotating valve is on the valve assembly properly seated The platelet cuvette/valve assembly hasdriver. been designed so that the operator can easily install the platelet cuvette/valve assembly while insuring that the platelet cuvette is properly seated in the platelet sensor and that the rotating valve is properly PRP Valve luer lock syringe seated on thePort: valveAassembly driver. is attached to the PRP valve port to collect PRP. At the end of a processing cycle, the PRP valve port can also be used to collect PPP. A Syringe Activated Valve is included as an accessory and can be A luer lock syringe is attached to syringe the PRPisvalve port to collect PRP. At the end of a processing cycle, the PRP Value attached toPort: maintain a closed port when the PRP removed. PRP valve port can also be used to collect PPP. A syringe-activated valve is included as an accessory and can be attached to maintain a closed port when the PRP syringe is removed. IFU011644/03 IFU011644/02 Cytomedix, Inc. Cytomedix, Inc.  Cytomedix, Inc.  12-CYTO-0439 Instructions for Use Document_v3.indd 1  10/9/13 2:31 PM
File Type: PDF
File Size: 657 KB
File Name: angel_cprp_system_processing_set_instructions_for_u.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions