Edwards Lifesciences

HemoSphere Advanced Monitoring Setup Guide v 1.0

Setup Guide

4 Pages

HemoSphere Advanced Monitoring Platform  HemoSphere Swan-Ganz module setup 3 2  6  4  1. Compatible Swan-Ganz catheter 2. Thermal filament connection 3. Thermistor connection  Setup guide 7 4. I njectate temperature probe connection 5. Patient CCO cable 6. HemoSphere Swan-Ganz module 7. H  emoSphere advanced monitor  HemoSphere Swan-Ganz module setup 1. I nsert the HemoSphere Swan‑Ganz module into a standard module slot on the left panel of the HemoSphere advanced monitor. The module will click in place when properly engaged. 2. Turn on monitor power switch and follow steps for entering patient data. 3. Plug the patient CCO cable into the module using the connection guide arrows for proper orientation. For CCO cable test, refer to ops manual. 4. C  onnect the compatible Swan‑Ganz catheter to the patient CCO cable. 5. R  efer to the HemoSphere advanced monitor operator’s manual for catheter connection guidelines and monitoring procedures. 24/7 technical support 800-822-9837 capital_care@edwards.com  For professional use. CAUTION: Federal (United States) law restricts this device to sale by or on the order of a physician. See instructions for use for full prescribing information, including indications, contraindications, warnings, precautions and adverse events. Edwards Lifesciences devices placed on the European market meeting the essential requirements referred to in Article 3 of the Medical Device directive 93/42/EEC bear the CE marking of conformity. Edwards, Edwards Lifesciences, the stylized E logo, HemoSphere, Swan, and Swan-Ganz are trademarks of Edwards Lifesciences Corporation. All other trademarks are the property of their respective owners. © 2017 Edwards Lifesciences Corporation. All rights reserved. PP--US-2208 v1.0 Edwards Lifesciences One Edwards Way, Irvine CA 92614 USA edwards.com  HemoSphere advanced monitor setup  HemoSphere platform  1  5  5  1. S  ecurely position the HemoSphere advanced monitor or mount on a compatible stand.  1  2. Open the battery door on the lower right panel of the HemoSphere advanced monitor and insert the battery. 3. Connect the power cord to the rear panel of the monitor and plug into a hospital grade outlet. Note: after inserting the battery for the first time, the battery must be fully charged and conditioned. Refer to operator’s manual for additional information. 4. Insert desired hemodynamic technology module and/or cable. Refer to module or cable instructions for proper insertion/connection procedures.  2  5. Press power button on the front of the monitor. Note: upon initial startup the display language can be selected which affects the time/date format and units of measurement. 6. Follow instructions contained in the HemoSphere advanced monitoring platform operator’s manual for desired hemodynamic technology module or cable monitoring.  4 3
File Type: PDF
File Size: 795 KB
File Name: hemosphere_advanced_monitoring_setup_guide_v_1-0.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions