Arsenal Plating System Cleaning and Sterilization Protocol

1 Page

CLEANING AND STERILIZATION PROTOCOL Arsenal Plating System CLEANING 7. Non-sterile products must be carefully and thoroughly cleaned prior to sterilization. Trained personnel must perform cleaning and 8. mechanical inspection prior to sterilization. Compliance is required with the equipment manufacturer’s user instructions (manual and/or 9. machine cleaning, ultrasound treatment, etc.) and recommendations for chemical detergents. System Instrumentation Disassembly Instructions: The provided Depth Gauges (330-22-005, 330-27-005) should be properly disassembled prior to cleaning. The following instructions demonstrate how to properly disassemble the provided Depth Gauges prior to cleaning and then reassemble: 1. To remove the cone piece without wire damage, tap the back of the depth gauge firmly on a table. DO NOT REMOVE THE ATTACHED WIRE.  Remove parts from bath and rinse using reverse osmosis/ deionized (RO/DI) water Fill syringe with RO/DI water (60mL) and flush part cannulation, where applicable Transfer parts into automated washer (STERIS® Reliance Genfore) for processing using the following parameters: Recirculation Temperature Time  Phase  Detergent Type and Concentration  Pre-wash 1  02:00  Cold tap water  N/A  Enzyme Wash  02:00  Hot tap water  Enzol® 1 oz/gal  Wash 1  02:00  65.5°C  Prolystica® 2X Neutral 1/8 oz/gal  Rinse 1  01:00  Hot tap water  N/A  Drying  15:00  90°C  N/A  2. To reassemble after cleaning, pull the slide back through the 10. Visibly inspect for remaining soil on part body to protect the wire and snap the cone piece onto the body. 11. If the part is not visibly clean, repeat steps 1-10 3. Proceed to Calcaneal Slide Plate Placement Guide disassembly instructions. Recommended Manual Cleaning Instructions: 1. Rinse with tap water to remove gross soil The provided Calc Slide Plate Placement Guide (330-86-001) 2. Inject water (60mL) into cannulation to remove gross soil should be properly disassembled prior to cleaning. The following 3. Prepare enzymatic detergent (Enzol®) at manufacturer instructions demonstrate how to properly disassemble the provided recommendation (1oz/gal) using lukewarm tap water and fully Calc Slide Plate Placement Guide prior to cleaning: immerse parts 1. Unthread the two screws by rotating counterclockwise to 4. Use a soft bristled brush (Spectrum M16 or equivalent) and separate as shown: appropriately sized lumen brush to brush all surfaces 5. Use syringe to inject detergent (60mL) into cannulation 6. Allow articles to dwell in detergent bath for 1 minute 7. Remove parts from bath and rinse using reverse osmosis/ deionized (RO/DI) water 8. Fill syringe with RO/DI water (60mL) and flush part cannulation, where applicable 9. Allow parts to air dry. A clean lint-free cloth may be used to aid in drying 10. Visibly inspect for remaining soil on part  2. Proceed to Cleaning Instructions. Instrumentation Cleaning Instructions Trilliant Surgical recommends the following cleaning and sterilization instructions: Recommended Automatic Cleaning Instructions: 1. Rinse with tap water to remove gross soil 2. Inject water (60mL) into cannulation to remove gross soil 3. Prepare enzymatic detergent (Enzol®) at manufacturer recommendation (1oz/gal) using lukewarm tap water and fully immerse parts 4. Use a soft bristled brush (Spectrum M16 or equivalent) and appropriately sized lumen brush to brush all surfaces 5. Use syringe to inject detergent (60mL) into cannulation 6. Allow articles to dwell in detergent bath for 1 minute  NON-STERILE PRODUCT STERILIZATION Trilliant Surgical Implant Systems can be packaged non-sterile and therefore must be sterilized prior to surgical use. Use of the sterilizer shall comply with the manufacturer’s user instructions. The user facility must thoroughly clean and disinfect instruments prior to sterilization per standard hospital procedures. Non-sterile devices are sterilizable by steam sterilization (autoclaving). The following parameters should be followed: Sterilization Method  Pre-Vacuum Steam  Condition  Wrapped*  Temperature  270°F (132°C)  Time  4 minutes  Recommended Dry Time  60 minutes  * The system shall be packaged for sterilization by double wrapping in an FDA cleared wrap and wrapping techniques outlined per ANSI/AAMI ST79, then adhered with FDA cleared chemical indicator autoclave tape. Note: Do not stack trays during sterilization.  This document is controlled by Trilliant Surgical. When downloaded, printed, and/or copied, this document becomes UNCONTROLLED and users should always check Trilliant Surgical’s website, www.trilliantsurgical.com, to ensure they have the latest version. Trilliant Surgical 727 North Shepherd Drive Suite 100 | Houston, TX 77007 Phone: 800-495-2919 | Fax: 877-778-3864 | www.trilliantsurgical.com  Page 1 of 1 900-06-021 Rev A
File Type: PDF
File Size: 262 KB
File Name: Trilliant Surgical - DJO Surgical - 900-06-021 - Arsenal Plating System Cleaning and Sterilization Protocol - Rev A.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions