Trilliant Surgical

Tiger Cannulated and Tiger Headless Cannulated Screw Systems Cleaning and Sterilization Protocol

1 Page

CLEANING AND STERILIZATION PROTOCOL Tiger Cannulated & Tiger Headless Cannulated Screw Systems CLEANING  Non-sterile products must be carefully cleaned prior to sterilization. Trained personnel must perform cleaning and mechanical inspection prior to sterilization. Compliance is required with the equipment manufacturer ’s user instructions (manual and/or machine cleaning, ultrasound treatment, etc.) and recommendations for chemical detergents. Trilliant Surgical recommends the following cleaning and sterilization instructions:  Recommended Automatic Cleaning Instructions: 1. Rinse with tap water to remove gross soil 2. Inject water (60mL) into cannulation to remove gross soil 3. Prepare enzymatic detergent (Enzol®) at manufacturer recommendation (1oz/gal) using lukewarm tap water and fully immerse parts 4. Use a soft bristled brush (Spectrum M16 or equivalent) and appropriately sized lumen brush to brush all surfaces 5. Use syringe to inject detergent (60mL) into cannulation 6. Allow articles to dwell in detergent bath for 1 minute 7. Remove parts from bath and rinse using reverse osmosis/deionized (RO/DI) water 8. Fill syringe with RO/DI water (60mL) and flush part cannulation, where applicable 9. Transfer parts into automated washer (STERIS® Reliance Genfore) for processing using the following parameters: Phase  Recirculation Time  Temperature  Detergent Type and Concentration  Pre-wash 1  02:00  Cold tap water  N/A  Enzyme Wash  02:00  Hot tap water  Enzol® 1 oz/gal  Wash 1  02:00  65.5°C  Prolystica® 2X Neutral 1/8 oz/gal  Rinse 1  01:00  Hot tap water  N/A  Drying  15:00  90°C  N/A  10. Visibly inspect for remaining soil on part  Recommended Manual Cleaning Instructions: 1. Rinse with tap water to remove gross soil 2. Inject water (60mL) into cannulation to remove gross soil 3. Prepare enzymatic detergent (Enzol®) at manufacturer recommendation (1oz/gal) using lukewarm tap water and fully immerse parts 4. Use a soft bristled brush (Spectrum M16 or equivalent) and appropriately sized lumen brush to brush all surfaces 5. Use syringe to inject detergent (60mL) into cannulation 6. Allow articles to dwell in detergent bath for 1 minute 7. Remove parts from bath and rinse using reverse osmosis/deionized (RO/DI) water 8. Fill syringe with RO/DI water (60mL) and flush part cannulation, where applicable 9. Allow parts to air dry. A clean lint-free cloth may be used to aid in drying 10. Visibly inspect for remaining soil on part  NON-STERILE PRODUCT STERILIZATION Trilliant Surgical Implant Systems can be packaged nonsterile and therefore must be sterilized prior to surgical use. Use of the sterilizer shall comply with the manufacturer’s user instructions. The user facility must clean and disinfect instruments prior to sterilization per standard hospital procedures. Non-sterile devices are sterilizable by steam sterilization (autoclaving). The following parameters should be followed: Sterilization Method  Pre-Vacuum Steam  Gravity Steam  Condition  Wrapped*  Wrapped*  Temperature  270°F (132°C)  270°F (132°C)  Time  4 minutes  40 minutes  Dry Time  Recommended 50 minutes**  Recommended 50 minutes**  *The system shall be packaged for sterilization by double wrapping in standard central supply wrap (i.e. Bio-Shield® Sterilization Wrap). **Trilliant Surgical has validated the recommended sterilization cycle and dry time for trays. The dry time varies due to load configuration, wrapping method, and material.  This document is controlled by Trilliant Surgical. When downloaded, printed, and/or copied, this document becomes UNCONTROLLED and users should always check Trilliant Surgical’s website, www.trilliantsurgical.com, to ensure they have the latest version.  Trilliant Surgical 727 North Shepherd Drive Suite 100 | Houston, TX 77007 Phone: 800-495-2919 | Fax: 877-778-3864 | www.trilliantsurgical.com  Page 1 of 1 900-06-007 Rev F
File Type: PDF
File Size: 135 KB
File Name: Trilliant Surgical - DJO Surgical - 900-06-007 - Tiger Cannulated and Tiger Headless Cannulated Screw Systems Cleaning and Sterilization Protocol - Rev F.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions