AtriCure Inc

Robotic Slim Blade*

Window Access Retractor SI System Instructions for Use

3 Pages

Instructions for Use Window Access Retractor SI System Non-Sterile PRODUCT DESCRIPTION Catalog Number 400-150, 400-400, 400-171, 400-172, 400-173, 400-181, 400-182, 400-183, 400-191, 400-192, 400-193 The Window Access Retractor SI System is a reusable system comprised of two different Parallel Thoracotomy Retractor Bodies (standard and short rack) and several different MV Retractor Blade Sets (standard, slim, and angled). The Window Access System has several threaded receptacles for mounting accessory devices on the retractor body. CLEANING AND STERILIZATION Refer to 440-11975 - Instructions for Reprocessing of Reusable Devices for cleaning and sterilization information. This document is available at www.estech.com USE OF DEVICE 1. Attach the desired retractor blades to the retractor by pressing the blade-mounting pin into the blade receptacle in the retractor body until it clicks securely into place. See figure 1. 2. Make appropriate surgical incision. 3. Insert retractor blades into incision. 4. Turn retractor opening adjustment knob counterclockwise until desired width of opening is achieved. See Figure 1 5. To remove retractor, depress the ratchet and slide the two arms of the retractor together. NOTE: The 120 mm retractor body should only be used with the slim blades to provide the appropriate amount of retraction. WARRANTY AtriCure warrants that reasonable care has been used in the design and manufacture of this instrument. This warranty is in lieu of and excludes all other warranties not expressly set forth herein, whether expressed or implied by operation of law or otherwise, including, but not limited to, any implied warranties of merchantability or fitness for a particular use. Handling , storage, cleaning and sterilization of this instrument as well as other factors relating to the patient, diagnosis, treatment, surgical procedures, and other matters beyond AtriCure control directly affect the instrument and the result obtained from it s use. AtriCure’s obligation under this warranty is limited to the repair or replacement of this instrument and AtriCure shall not be liable for any incidental or consequential loss, damage, or expense directly or indirectly arising from the use of this instrument. AtriCure neither assumes, nor authorizes any other person to assume for it, any other or additional liability or responsibility in connection with this instrument. AtriCure assumes no liability with respect to instruments reused, reproces sed or re-sterilized and makes no warranties expressed or implied, including but not limited to merchantability or fitness for intended use, with respect to such instrument.  SERVICE OR REPAIR /TECHNICAL INFORMATION Contact information for service, repair or to request technical information:  Manufactured by: AtriCure Incorporated 7555 Innovation Way Mason, Ohio 45040 USA Customer Service: 1-866-349-2342 (toll free) 1-513-755-4100 (phone) 430-13853-01 Rev D  European Representative: Köntges SPRL Avenue Hellevelt 35 B-1180 Brussels Belgium Tel: +32 (0) 2 375 51 63 FAX: +32 (0) 2 375 89 06 e-mail: herbert.kontges@skynet.be PROPRIETARY & CONFIDENTIAL  Page 1 of 3
File Type: PDF
File Size: 312 KB
File Name: AtriCure Inc - 430 - 13853 - 01 - Window Access Retractor SI System Instructions for Use - Rev D.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions