AtriCure Inc

Suture Catcher

Suture Catcher Instruction for Use

4 Pages

INSTRUCTIONS FOR USE Catalog Number 340-7475 Least Invasive Valve Instruments™ Suture Catcher External view  Tip area  INTRODUCTION These instructions are designed to provide general instructions and suggestions on how to use the Estech Suture Catcher. The instructions are intended for use to advance surgeon controlled Suture Catcher placement in cardiothoracic procedures requiring remote suture catcher placement. The operation of a suturing thread or similar item is caught on the suture hook at the tip and can thereby be moved to a desired location during surgery.  PRODUCT DESCRIPTION/INDICATIONS FOR USE The Suture Catcher is comprised of stainless steel. The overall length is 350 mm (13.75 inches) and the tip is approximately 5 mm (0.72 inches) long. The device is used to facilitate manipulation of suture during surgery. The principal use of the Estech Suture Catcher is to capture a suture placed deep in the thoracic cavity, which is to be retrieved. It is most commonly used to pull the suture through tissue out of the chest wall for pericardial and/or tissue retraction. This product is non-sterile.  GENERAL WARNINGS 1. United States Federal Law restricts this device to sale by or on the order of a physician or other licensed practitioner. 2.  Improper usage may damage this product. Excessive force may cause the instrument tip to fracture, which may lead to breaking off during the surgical procedure.  3.  Do not modify, or otherwise alter this product (intended function may no longer be maintainable).  4.  Do not use hydrochloric acid, sulfuric acid, nitric acid, or other mineral acids (inorganic acids) or strong abrasive agents on this product (usable life may be shortened).  5.  No element of the process temperature must not reach 140° C (284° F) or higher.  6.  Check for damage or other problems before use. Do not use a device showing any wear, deterioration, corrosion, deformation, pitting or other damage.  7.  Before use, always wash/sterilize. Follow the “Instructions for Use” and the sterilizer processing parameters for appropriate method, temperature and time.  430-14572-01 Rev. C  PROPRIETARY & CONFIDENTIAL  Page 1 of 4
File Type: PDF
File Size: 337 KB
File Name: AtriCure Inc - 430 - 14572 - 01 - Suture Catcher Instruction for Use - Rev C.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions