Intuitive Surgical

Endoscope Cannula Mount

da Vinci Xi Reprocessing Wall Chart

1 Page

da Vinci Xi Reprocessing Xi ENDOSCOPE Inspect  7 Flush Flush all ports with pressurized cold water.  6 x 20 sec  Connector Cover (if present) 2 Clean Wipe thoroughly using disinfectant, dry, and attach cover.  8 Spray Submerge and spray gap and base.  2 x 20 sec  Solution 3 Prepare Prepare enzymatic solution (pH 7-11).  9 Brush Brush submerged or under running cold water.  60 sec  4 Prime Prime button ports, input discs, and base with enzymatic solution.  Rinse 10 Final Rinse with critical water.  60 sec  5 Soak Soak endoscope and cable.  15 min  11 Inspect Inspect entire endoscope for soil.  6 Rinse Rinse under running cold water.  60 sec  Chemical Disinfection (optional) 12 Apply per manufacter’s instructions and rinse.  1  Inspect entire endoscope for damage.  da Vinci Universal Reprocessing INSTRUMENTS AND STAPLER  8 Rinse Rinse under running cold water.  60 sec  Solution 2 Prepare Prepare enzymatic solution (pH 7-11).  Cleaning 9 Ultrasonic Prime and clean in ultrasonic bath.  15 min  3 Prime Prime primary port with enzymatic solution.  10 Flush Flush ports with pressurized cold water.  20 sec  4 Soak Soak the device.  30 min  Rinse 11 Final Rinse with critical water.  60 sec  20 sec  12 Inspect Inspect entire device for soil.  6 Spray Submerge and spray tip.  30 sec  Thermal Disinfection (optional) 13 Disinfect per hospital policy.  7 Brush Brush submerged or under running cold water.  60 sec  1  Remove Accessories Remove all accessories before cleaning.  5 Flush Flush all ports with pressurized cold water.  ACCESSORIES GROUP 1 Cannulae, Obturators, Release Kits, Hasson Cone, Instrument Introducers, Gage Pins, Suction Irrigator Kit, etc.  Ultrasonic Cleaning (optional) 6 Clean in ultrasonic bath.  15 min  Solution 2 Prepare Prepare enzymatic solution (pH 7-11).  Rinse 7 Final Rinse with critical water.  10 sec  3 Soak Soak and actuate moving parts.  10 min  8 Inspect Inspect entire device for soil.  4 Rinse Rinse under running cold water.  20 sec  Thermal Disinfection (optional) 9 Disinfect per hospital policy.  5 Brush Brush submerged or under running cold water.  60 sec  1  Remove Accessories Remove all accessories before cleaning.  ACCESSORIES GROUP 2 Cautery Cord, Stapler Cable, PK Cords, Light Guide Cable, etc.  1  Disconnect Cords or Cables  Rinse 5 Final Rinse with critical water.  Disconnect all cords and cables from device.  Solution 2 Prepare Prepare enzymatic solution (pH 7-11).  6 Inspect Inspect entire accessory for soil.  3 Wipe Wipe thoroughly using enzymatic solution.  Thermal Disinfection (optional) 7 Disinfect per hospital policy.  4 Brush Brush submerged or under running cold water.  60 sec  60 sec  Intuitive Surgical, Inc. 1266 Kifer Road Sunnyvale, CA 94086 USA Customer Service 800.876.1310 Copyright © 2017 Intuitive Surgical, Inc. All rights reserved. Intuitive®, Intuitive Surgical®, da Vinci® S™, da Vinci® Si™, da Vinci® X™, da Vinci® Xi™, and EndoWrist® are registered trademarks of Intuitive Surgical, Inc. Other brand and product names are trademarks or registered trademarks of their respective holders. PN 554059-01 Rev. A  For Intuitive Surgical da Vinci® X/Xi™ Surgical System Instruments, Stapler, and Endoscopes. This chart is not intended to replace an in-service or a manual. Refer to da Vinci X/Xi Reprocessing Instructions and da Vinci X/Xi Stapler Reprocessing Instructions.
File Type: PDF
File Size: 1010 KB
File Name: Intuitive Surgical - Intuituve Sugical - PN 554059-01 - da Vinci Xi Reprocessing Wall Chart - Rev. A.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions