KARL STORZ ENDOSKOPE

Bipolar Coagulation

Instruments For Bipolar Coagulation Instruction Manual

32 Pages

D  Instrumente für Bipolar-Koagulation  Modelle 840036, 840036E 97000333  E  GEBRAUCHSANWEISUNG  Symbolerläuterungen  33 22  Instruments for bipolar coagulation  Hersteller Symbol description  33 22  WARNING: Failure to observe may result in injury or even death.  CAUTION: Failure to observe may result in damage to or even destruction of the product.  11  NOTE: Special information on the operation of the instrument. Consult instructions for use Manufacturer  Explicación de los símbolos  33 22  CUIDADO: La inobservancia de este aviso podría conllevar lesiones o incluso la muerte. ADVERTENCIA: La inobservancia de este aviso podría conllevar deterioros o incluso la destrucción del producto.  11  NOTA: Informaciones especiales para el manejo del instrumento. Consúltense las instrucciones de uso Fabricante  1    HINWEIS: Spezielle Informationen zur Bedienung des Instrumentes. Gebrauchsanweisung beachten  Modelos 840036, 840036E  840036  VORSICHT: Nichtbeachtung kann zur Beschädigung oder Zerstörung des Produktes führen.  11  MANUAL DE INSTRUCCIONES  Instrumentos para coagulación bipolar  Models 840036, 840036E  1  WARNUNG: Nichtbeachtung kann Verletzungen oder Tod zur Folge haben.  ES  INSTRUCTION MANUAL       1 Elektrodenspitze 2 Anschluss für HF-Kabel 3 Absauganschluss 4 Elektrodenanschlussbuchse 5 Koagulations-Elektrode 840036E  1 Electrode tip 2 Connection for HF cable 3 Suction device connection 4 Electrode connection socket 5 Coagulation electrode 840036E  1 Punta del electrodo 2 Conexión para el cable de AF 3 Conexión de aspiración 4 Conector para electrodos 5 Electrodo de coagulación 840036E  1  Zweckbestimmung  1  Intended use  1  Uso previsto  2  Indikationen  2  Indications  2  Indicaciones  3  Kontraindikation  3  Contraindications  3  Contraindicaciones  Koagulationsinstrumente dienen dem Dissezieren, Präparieren, Fassen und Koagulieren, Modelle mit Absauganschluss dienen zusätzlich dem Absaugen von Flüssigkeiten und Gewebe, in der HNO-Heilkunde. Koagulationsinstrumente sind zur vorübergehenden Anwendung sowohl bei chirurgisch-invasiven, als auch bei natürlich invasiven Eingriffen bestimmt.  Der Einsatz des Instrumentariums ist indiziert, wenn es aus Sicht des behandelnden Arztes indiziert ist. Dazu gehören unter anderem: • Rhinologie, Rhinoplastik • Sinuschirurgie und transnasaler Zugang zur externen Schädelbasischirurgie • Ohrdiagnostik und Ohrchirurgie • Adenotomie, Tonsillektomie, Tracheotomie • Laryngoskopie, endolaryngeale Mikrolarynx- und transorale Mikrochirurgie • Oesophagoskopie, Divertikuloskopie  Der Einsatz des Koagulationsinstrumentariums ist dann kontraindiziert, wenn nach Einschätzung des behandelnden Arztes die OP-Methode kontraindiziert ist oder aufgrund des Allgemeinzustands des Patienten die OP- bzw. Narkosefähigkeit nicht gegeben ist. Das Koagulationsinstrumentarium darf nicht für Eingriffe in direktem Kontakt mit dem ZNS (Zentralen Nervensystem) und zentralen Herzkreislaufsystem verwendet werden.  Coagulation instruments are used to dissect, prepare, grasp, and coagulate. Models with a suction connection are also used for suctioning fluids and tissue in ENT medicine. Coagulation instruments are intended for transient use in both surgical invasive interventions and interventions performed through natural orifices.  The use of the instrument set is indicated if it is indicated in the opinion of the attending physician. This includes, amongst other things: • Rhinology, rhinoplasty • Sinus surgery and transnasal access for external skull base surgery • Ear diagnostics and ear surgery • Adenotomy, tonsillectomy, tracheotomy • Laryngoscopy, endolaryngeal microlarynx and transoral microsurgery • Esophagoscopy, diverticuloscopy  The use of the coagulation instrument set is contraindicated if, in the opinion of the attending physician, the surgical method as such is contraindicated or if the patient is not able to undergo surgery or anesthesia due to his or her general condition. The coagulation instrument set must not be used for interventions in direct contact with the central nervous system (CNS) and central cardiovascular system.  Los instrumentos de coagulación sirven para diseccionar, preparar, sujetar y coagular; los modelos con conexión de aspiración sirven además para aspirar líquidos y tejido en otorrinolaringología. Los instrumentos de coagulación están previstos para aplicaciones transitorias tanto en intervenciones quirúrgicas invasivas como en intervenciones invasivas a través de orificios naturales. La utilización del instrumental está indicada cuando, según la opinión del médico encargado del tratamiento, esta esté indicada. Entre estas indicaciones se incluyen: • Rinología, rinoplastia • Cirugía de los senos nasales y acceso transnasal para la cirugía externa de la base del cráneo • Diagnóstico del oído y cirugía del oído • Adenotomía, amigdalectomía, traqueotomía • Laringoscopia, cirugía microlaríngea endolaríngea y microcirugía transoral • Esofagoscopia, diverticuloscopia La utilización de instrumentos de coagulación está contraindicada cuando, según la opinión del médico encargado del tratamiento, el método quirúrgico en sí esté contraindicado o, debido al estado general del paciente, no pueda administrarse anestesia o practicarse cirugía. Los instrumentos de coagulación no deben utilizarse en intervenciones que requieran contacto directo con el sistema nervioso central (SNC) y el sistema cardiocirculatorio central.  KARL STORZ SE & Co. KG, Dr.-Karl-Storz-Straße 34, 78532 Tuttlingen, Germany, Phone: +49 7461 708-0, Fax: +49 7461 708-105, E-Mail: info@karlstorz.com  V 1.0 – 07/2020
File Type: PDF
File Size: 1.04 MB
File Name: KARL STORZ ENDOSKOPE - 97000333 - Instruments For Bipolar Coagulation Instruction Manual - 2020-07 - V 1.0.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions