12 in. x 3 in. Weinstein Instrument Sterilizing Rack
Genesis Sterilization Container System Accessories Instructions
5 Pages
Preview
Page 1
V. Mueller™ Genesis™ Sterilization Container System Accessories
Contact Information: CareFusion 1500 Waukegan Road McGaw Park, IL 60085 U.S.A. 800-323-9088 Cleveland, OH U.S.A. 800.227.3220 440.243.2414 www.carefusion.com
© 2012 CareFusion Corporation or one of its subsidiaries. All rights reserved. CareFusion 1500 Waukegan Road McGaw Park, IL 60085 U.S.A. 36-10061 • 2012-06
V. Mueller and Genesis are trademarks of CareFusion Corporation or one of its subsidiaries. STERRAD® is a registered trademark of Advanced Sterilization Products, a Division of J & J Medical, Inc. This product is not manufactured or distributed by Advanced Sterilization Products, the owner of the registered trademark STERRAD®.
Catalog Numbers
Cautions
All Genesis baskets, organizational accessories, and single use accessories supplied by CareFusion, V.Mueller Products and Services covered by these instructions for use are listed in the appendix. These instructions for use do not provide a complete guide for sterilization and cleaning of the Genesis reusable rigid container system. See the Genesis Sterilization Container Operators Manual for additional detail.
If there are any variations between these instructions and either your facility’s policies and/or your cleaning/sterilizing equipment manufacturer’s instructions those variations should be brought to the attention of the appropriate responsible hospital personnel for resolution before proceeding with cleaning and sterilizing these accessories. Prior to use, all accessories should be inspected to ensure proper function and condition. Do not use accessories if they do not satisfactorily perform their intended function or have physical damage.
Intended Use The Genesis reusable rigid container system is a device intended to be used to enclose another medical device that is to be sterilized by a healthcare provider. It allows sterilization of the enclosed medical device and maintains sterility of the enclosed device until used.
Only one DST-series filter sheet, or thickness, should be used underneath each retention plate per process. Using more than one thickness or sheet of the filter has not been validated for efficacy.
Baskets and organizational accessories are intended to organize and secure medical devices during sterilization, transport, and storage of the container. Single use accessories, including the DST-series filter sheets, tamper-evident arrows, and data cards are intended to be used with the Genesis reusable rigid container systems and aid in sterilization processing and storage. Refer to the Genesis Sterilization Container Operators Manual for complete details on assembly, use and processing.
Sterilizers vary in design and performance characteristics. It is strongly recommended that the user verify the cycle parameters for the specific sterilizer prior to use. Adjusted cycle times may be required to properly sterilize desired loads. The accessories listed in the appendix have only been validated for use with Genesis reusable rigid container systems using the parameters defined in the Genesis Sterilization Container Operators Manual. If Instruction for Use are needed, contact your local V. Mueller representative or distributor or call the customer service center at 800.227.3220.
How Supplied Baskets, organizational accessories, and single use accessories are packaged as non-sterile. Baskets and organizational accessories must undergo cleaning prior to use.
Pre-processing Instructions Refer to the Genesis Sterilization Container Operators Manual for complete pre-processing and assembly instructions.
Limitations on Reprocessing Repeated processing has minimal effect on the baskets and organizational accessories. End of life is normally determined by wear and damage due to use. Single use accessories must be discarded after each process.
Select appropriate size filter according to the retention plate size. Each sterilant access (perforated) area requires one filter. The sterilant access area(s) is located in the container lids and in the bottoms of select container devices. Prior to insertion, inspect each filter to ensure it is free of any holes, tears or punctures which could adversely affect its performance.
Warnings Baskets, organizational accessories, and single use accessories shall be used in accordance with these instructions and the Genesis Sterilization Container Operators Manual. Read all sections of this insert prior to use. Improper use of these accessories may result in a non-sterile set after processing. In addition, improper care and maintenance of these accessories may render the accessories non-sterile prior to patient use and may cause serious injury to patient or healthcare provider.
Select appropriate tamper-evident arrow according to intended sterilization modality. White tamper-evident arrows are intended for steam modalities, yellow for Ethylene Oxide, and pink (fuchsia) for STERRAD 50 and 100S.
Manual and Automatic Cleaning Refer to the Genesis Sterilization Container Operators Manual for complete cleaning instructions and parameters compatible with the baskets and organizational accessories.
Do not use filter materials in the presence of flammable anesthesia. A safety hazard may be created. Filter materials other than the Genesis DST-series filters have not been validated for use with the Genesis reusable rigid containers. Follow the Modality Specific Recommendations for Accessories and Containers found in the Genesis Sterilization Container Operators Manual for determining proper container system setup and validated processing methods and parameters.
1
Inspection/Maintenance
Warranty
The Genesis accessories should be routinely inspected for damage which could result in the product not functioning as intended. Baskets and organizational accessories should be inspected for dents, sharp edges/corners, and proper function to ensure they are in good working order prior to use. Filters should be inspected for tears, punctures, and creases/folds which could adversely affect performance. Tamper-evident arrows should be inspected to ensure the chemical indicator dot has not undergone a premature color change.
Genesis baskets and organizational accessories are warranted for their lifetime to be free of functional defects in both materials and workmanship when used normally for their intended purpose of securing and organizing surgical instruments in the Genesis reusable rigid container systems. Any Genesis accessory proving to be so defective will be repaired or replaced at no charge.
Arrow
Pre-Process Dot Color
Post-Process Dot Color
White - Steam
White
Dark Gray or Black
Yellow Ethylene Oxide
Blue
Green
Pink (fuchsia) STERRAD
Yellow
Blue
Repairs or modifications performed by unauthorized personnel may void all product warranties and could affect performance and efficacy of device.
Repair Service Authorization is required before returning any item for Credit, Repair or Warranty replacement. Please contact your local V. Mueller representative or distributor or call the customer service center at 800.227.3220 for a Return Goods Authorization number. IMPORTANT: All devices being returned for maintenance, repair, etc. must be cleaned and sterilized per these instructions for use prior to shipment.
The degree of color change is not significant, as this color change is not an indication of sterility but that the process indicator dot (reactive chemical applied to the dot) has been exposed to specific sterilization parameters.
Pack goods securely to avoid damage during shipment. When shipping multiple products in one carton, avoid metal-to-metal contact. New product that has not been processed or sterilized may be returned for credit within 90 days of invoice date. Determination of credit amount or warranty repair/replacement will be made at the Genesis facility.
Packaging Only Genesis filters, tamper-evident arrows, data cards, baskets, organizational accessories and repair parts are validated for use with the Genesis reusable rigid sterilization container systems. Do not use unauthorized single use accessories or container products with the Genesis reusable rigid sterilization container system.
Do not use foam peanuts, newspaper or inflatable air packs. If you are in need of proper shipping material, contact your local V. Mueller representative or distributor or call the customer service center at 800.227.3220. Parts that are faulty due to defects in material or workmanship will be repaired or replaced at no charge. Parts that have been misused or mishandled are not covered under warranty. Used or processed items may not be returned for credit.
Sterilization Genesis reusable rigid sterilization container systems have been validated for use in Pre-Vacuum Steam, Gravity Displacement Steam, 100% Ethylene Oxide, and STERRAD 50 and 100S sterilizers. Refer to the Genesis Sterilization Container Operators Manual for proper assembly and sterilization of the Genesis reusable rigid container systems and accessories.
Contact Information: Contact your local V. Mueller representative or distributor or call the customer service center at 800.227.3220 with any questions or requests for additional information pertaining to your Genesis reusable rigid sterilization container system or accessories.
The same filter material (DST-series) has been validated for use in steam, 100% Ethylene Oxide, and STERRAD 50 and 100S sterilization modalities.
Storage When properly processed, Genesis reusable rigid sterilization container systems and validated accessories can be stored for up to 180 days. Refer to the Genesis Sterilization Container Operators Manual for additional information.
Other Resources: For additional information and detailed instructions on use, assembly and processing, refer to the Genesis Sterilization Container Operators Manual.
2
Appendix
Organizational Accessories
Baskets
DIN05-6237 DIN05-6238 DIN2087
DIN2088
DIN2089
DINGR1894 DP1-1
DP1-2
DP1-3
DP1-4
DP1-5
BP0-1A
BP0-2A
BP0-2V
BPS0-2A BP1-1AS
BP1-2A
BP1-2AS BP1-2V
BP1-2VS BP1-3A
GR1807
GR1808-1
GR1808-3
GR1808-4
BP1-3V
BP1-4A
BP1-4V
BPS1-2A BPS1-3A
GR1808-5
GR1808-6
GR1808-7
GR1808-8
BPS1-4A BP2-1AS BP2-2A
BP2-2AS BP2-2V
GR1808-9
GR1892-1
GR1892-10 GR1892-11
BP2-2VS BP2-3A
BP2-4A
GR1892-12 GR1892-2
GR1892-3
GR1892-4
GR1892-5
GR1892-6
GR1892-7
GR1892-8
GR1892-9
GR1893-1
GR1893-2
GR1893-3
BP2-5A
BP2-6A
BP2-3V BP2-6V
BP2-4V
BPS2-2A BPS2-3A
BPS2-4A BPS2-6A BP3-1AS BP3-2A
BP3-2AS
BP3-2V
BP3-2VS BP3-3A
BP3-3V
BP3-4A
BP3-4V
BP3-5A
BP3-5V
GR33322338 GR33322561 GR5300
GR5301
GR5302
GR5310
GR5311
GR5312
BPS3-2A BPS3-3A
GR5320
GR5330
GR5331
GR5332
BPS3-4A BPS3-5A BP4-2A
BP4-2AS BP4-2V
GR5333
GR5334
GR5335
GR5339
BP4-2VS BP4-4A
BP4-4V
BPS4-2A BPS4-4A
GR5340
GR5341
GR5350
GR5351
BP5-2AS BP5-2V
BP5-2VS BP5-3V
GR5352
GR5353
GR5354
GR5355
GR5370
GR5371
GR5372
GR5373
GR5374
GR5375
LP3-1
LP7-1
LP7-2
PP1-1
PP1-2
PP1-2.5
PP1-3
PP1-4
BP5-2A BP5-4A BP6-4V
BP5-4V
BPS5-2A BPS5-4A BP6-4A
BPS6-4A BP7-2AS BP7-3A
BP7-4A
BP7-4AS DINBP1-2A DINBP1-3A
DINBP1-4A
DINBP1-3V DINBP1-4V
DINBP1-2AS DINBP1-2VS
SX2-0
SX2-1
SX2-2
SX2-3
DINBP2-2A DINBP2-3A
DINBP2-4A
SX2-5
SX2-6
SX2972-1
SX2972-2
DINBP2-3V DINBP2-4V
DINBP2-2AS DINBP2-2VS
SX2972-3
SX2972-4
SX2972-5
SX2972-6
DINBP3-2A DINBP3-3A
DINBP3-4A
TB1-1
TB1-10
TB1-12
TB1-2
TB1-3
TB1-4
TB1-5
TB1-6
TB1-7
TB1-8
TB1-9
TB2-1
TB2-10
TB2-12
TB2-2
TB2-3
TB2-4
TB2-5
TB2-6
TB2-7
TB2-8
TB2-9
TB3-1
TB3-10
TB3-12
TB3-2
TB3-3
TB3-4
TB3-5
TB3-6
TB3-7
TB3-8
TB3-9
TB5-1
TC2-1
TC2-10
TC2-12
TC2-2
TC2-3
TC2-4
TC2-5
TC2-6
TC2-7
TC2-8
DINBP3-3V DINBP3-4V
DINBP1-2V
R-ALG00001 R-ALG00002 R-ALG00003 R-ALG00004
DINBP2-2V
DINBP3-2V
DINBP3-2AS DINBP3-2VS
TC2-9
3
Single Use Accessories AG2-1
AH2-1
AS2-2
AS2-3
R1792-A R1793-A R1794-A R1795-A R1796-A
DST-1 DST-2 DST-3 Replacement Parts
AG2-2
MD1-1
MH1-1
R1797-A R1798
R1004
R1039
R1041
R1043
R1046
R1828
R1047
R1063
R1072
R1073
R1074
R1841-A R1842-A R1843-A R1844
R1845
R1120
R1122
R1123
R1124
R1125
R1846
R1849
R1850
R1851
R1853
R1133
R1134
R1135
R1136
R1137
R1861
R1876
R1885
R1926
R1927
R1138
R1139
R1140
R1141
R1142
R1928
R1929
R1930
R1932
R1933
R1151
R1152
R1157
R1170
R1171
R1938-1 R1938-10 R1938-12 R1938-2 R1938-3
R1177
R1178
R1179
R1184
R1187
R1938-4 R1938-5 R1938-6 R1938-7 R1938-8
R1188
R1189
R1190
R1191
R1220
R1938-9 R1941
R1942
R1943
R1944
R1221
R1222
R1223
R1224
R1225
R1945
R1946
R1947
R1948
R1953
R1226
R1322
R1381
R1382
R1383
R1954
R1955
R1956
R1961
R1965
R1384
R1388
R1389
R1394
R1395
R1966
R1966ST R1967
R1968
R1968ST
R1413
R1415
R1502
R1512
R1514
R1969
R1970
R1522
R1542
R1589
R1590
R1591
R1972ST R1973
R1592
R1594
R1595
R1596
R1597
R1976
R1976ST R1977
R1621
R1623
R1624
R1626
R1645
R1979
R1980
R1671
R1672
R1693
R1694
R1695
R1982ST R1983
R1698
R1699
R1704
R1705
R1706
R1986
R1988
R1989
R1707
R1708
R1709
R1710
R1711
R2009-1 R2014
R2015
R2016
R2052
R1712
R1713
R1714
R1715
R1716
R2053
R2054
R2055
R2056
R2057
R1717
R1718
R1719
R1720
R1721
R2058
R2059
R2060
R2061
R2062
R1722
R1723
R1724
R1725
R1726
R2063
R2064
R2065
R2066
R2067
R1727
R1765
R1766
R1767
R1768
R2068
R2069
R2070
R2071
R2072
R1769
R1770
R1773
R1774
R1775
R2073
R2074
R2075
R2076
R2077
R1776
R1777
R1778
R1779
R1780
R2078
R2079
R2080
R2083
R2084
R1781
R1782
R1783
R1784
R1785
R2085
R2086
RP30-2
RP40-1
RP50-1
R1786
R1787
R1788
R1790-A R1791-A
R1827-1 R1827-2 R1827-3
R1827-4 R1827-5 R1827-6 R1827-7 R1827-8
RP50-2
4
R1829
R1831
R1832
R1970ST R1971 R1974
R1986ST R1987
R1972
R1974ST R1975 R1978
R1980ST R1981 R1984
R1840-A
R1978ST R1982
R1984ST R1985